Case Study · Thermal Imaging

Thermal Imaging: Micro-Coax Impedance Crisis Recovered, Partnership Saved

Joint root-cause analysis traced the failures to a spec-versus-test mismatch, driving updated specs and a replacement order for all 1,296 defective micro-coax assemblies.

Belgium · 2020 · Thermal Imaging harnesses

1,296 of 2,000 units recovered

AWG#40 micro-coax

Root cause + spec re-defined

Background

A European thermal imaging OEM ran a beta production series built on AWG#40 CABLINE-VS 1:1 100mm micro-coaxial cable assemblies. High-impedance defects triggered a critical production halt.

The Challenge

Of 2,000 micro-coax assemblies, 1,296 failed due to high impedance. The failures led to order cancellation, a demand for refunds, and a major trust deficit with the customer.

Our Solution

We halted production immediately and ran a joint technical analysis with the customer's engineering team, tracing the root cause to a mismatch between the specification definition and the testing method. We updated the specifications, issued new test reports, built new samples, and processed a replacement order for the defective units.

The Result

We resolved the quality complaint and secured a replacement order for all 1,296 defective units. The long-term partnership held despite the severe initial defect rate.

Program Specifications

GaugeAWG#40
CableCABLINE-VS 1:1, 100mm
Defective Units1,296 of 2,000
Replacement Units1,296